Eyes back on FHIR? An experimental continuation of the Eyes on FHIR working group's HL7 FHIR® IG
0.1.0 - experimental
Unknown region code '276'
Eyes back on FHIR? An experimental continuation of the Eyes on FHIR working group's HL7 FHIR® IG - Local Development build (v0.1.0) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions
Contents:
This page provides a list of the FHIR artifacts defined as part of this implementation guide.
These define constraints on FHIR resources for systems conforming to this implementation guide.
StructureDefinition/Posteriorsegment-narrative | |
StructureDefinition/PupillomotoricDiagnosticReport | |
StructureDefinition/pupil-comparison | |
StructureDefinition/pupil-diameter | |
Base ophthalmic Observation profile |
Base profile specifically constrained for describing ophthalmic Observations |
Intraocular Pressure (IOP) |
A measurement of a patient’s intraocular (within the eyeball) pressure (in mmHg). |
OCT RFNL Observations |
The Observations associated with the OCT RNFL DiagnosticReport (note: this valueset can also be used independently to describe specific findings/Observations captured by a OCT test, which may not necessarily be referenced by the DiagnosticReport.) |
OCT RNFL Diagnostic Report |
The DiagnosticReport profile for an OCT RNFL |
OCT macula Diagnostic Report |
The DiagnosticReport profile for an OCT macula |
OCT macula Observations |
The Observations associated with the OCT macula DiagnosticReport (note: this valueset can also be used independently to describe specific findings/Observations captured by a OCT test, which may not necessarily be referenced by the DiagnosticReport.) |
Ocular anatomical location |
The description of an ophthalmic anatomical site that is located within the following structures: the eyeball or the periocular or orbital regions (as opposed to non-ocular anatomical locations). This profile is used by combining the unique valueset (hyperlink) for relevant ophthalmic specific BodyStructure.locationQualifier (Body Site modifier) in combination with the base Observation BodyStructure.location (Body Site; descendants from SNOMED 371398005 (Eye Region Structure), each with a preferred binding in order to refine the accuracy of the location decription of occular structures. This unique qualifying element is important because these locations are routinely described either diffently and/or more granularly than other body parts. Of note - non occular (or surrounding) anatomical location references of Observations (eg - arm) do not need to use this modified specialty profile. |
Ophthalmic Diagnoses |
A profile to describe the formal past/present clinical diagnosis of a specific non-ophthalmic pathological Condition. As noted above, although the Condition Resource is also referenced in the non-ophthalmic findings profile, this profile is a modification of the base Condition Resource (as opposed to a base Obervation Resource modification, referencing Condition). |
Ophthalmic diagnostic test report |
Base profile specifically constrained for describing ophthalmic reports |
VF Diagnostic Report |
The DiagnosticReport profile for a visual field DT |
VF Observations |
The Observations associated with the VF DiagnosticReport (note: this valueset can also be used independently to describe specific findings/Observations captured by a VF test, which may not necessarily be referenced by the DiagnosticReport.) |
Visual Acuity (VA) |
An assessment of a patients ability to see. |
Visual Acuity (VA) V2 |
An assessment of a patients ability to see - Version two - simpler structure than Version 1 |
Visual Acuity (VA) V3 |
An assessment of a patients ability to see - Version three |
These define constraints on FHIR data types for systems conforming to this implementation guide.
StructureDefinition/LensDuringVATestSpecification |
Specification any Lens that was n front of an eye during a Visual Acuity test test |
StructureDefinition/OwnLensDuringVATestSpecification |
Specification of the Lens that was worn during the Visual Acuity test test |
These define sets of codes used by systems conforming to this implementation guide.
Intraocular pressure (IOP) method valueset |
Describes the various methods of capturing IOP that relate to the IOP Observation profile |
Lens Types |
This ValueSet includes all SNOMED CT codes that are descendants of ‘Contact lenses, device’ (57368009) and ‘Eye glasses, device’ (50121007). |
OCT Macula Observable Entities ValueSet |
OCT Macula observations coding |
OCT RNFL Observable Entities ValueSet |
OCT RNFL observations coding |
Observation Status |
Describes whether a recorded observation is either final or amended |
Ophthalmic anatomical location |
Describes the ophthalmic structure being referenced |
Ophthalmic anatomical location qualifiers |
Describes whether a recorded observation is either final or amended |
Ophthalmology Condition ICD10 and SNOMED codes ValueSet |
Clinical findings for the eye region. |
Ophthalmology Procedures Valueset |
This ValueSet represents procedure codes for clinical and billing purposes. |
Ophthalmology observations (SNOMED) |
Concept descends from 363926002 - Eye/vision observable (observable entity) |
Optotype Presentation ValueSet |
A ValueSet that includes codes representing the type of optotype presentation used during visual acuity testing. |
Optotype ValueSet |
A ValueSet that includes codes representing optotype used during visual acuity testing. |
Pinhole Occluder Usage Values |
This ValueSet contains SNOMED CT codes to represent whether a pinhole occluder was used during a visual acuity measurement. |
Pupil Function Confounders |
ValueSet including codes that represent confounders due to pupil function that may affect visual acuity measurements. |
Pupil Testing Active Substances |
This ValueSet contains codes to represent active substances used in pharmacological testing during pupil diameter measurements. |
Pupil-Diameter-Comparison |
A ValueSet containing codes for various pupillomotor function observations. |
Room Brightness Levels |
This ValueSet contains codes to represent the brightness of the room where a test was performed. |
Special VA testing Parameters |
This ValueSet contains codes to represent whether special testing parameters, such as a pinhole occluder or glare light, were used during a visual acuity measurement. |
ValueSet-right-left-both-eyes |
ValueSet containing laterality codes for ophthalmic observations which may contain information on one or both eyes |
ValueSet-right-left-eyes |
ValueSet containing laterality codes for ophthalmic observations which should only contain information on either the right or left eye, not both |
Visual Acuity Categorical Values |
ValueSet containing categorical values for visual acuity observations. |
Visual Acuity Correction Methods |
Methods of correction used during a visual acuity test. |
Visual Acuity Correction Methods |
Methods of correction used during a visual acuity test. |
Visual Acuity Measurement Methods valueset |
Describes the various charts that can be used to assess visual acuity where concept descends from 400912000 (Visual acuity test equipment (physical object)) |
Visual Acuity Quantity Units |
Units of Measure of Visual acuity |
Visual Acuity Test Distance |
Codes representing the distances at which visual acuity tests are performed. |
Visual Field Observable Entities ValueSet |
Visual field observation coding |
Visual acuity method valueset (SNOMED) |
Describes the visual acuity observation result, where concept descends from 363983007 (Visual acuity) |
These define new code systems used by systems conforming to this implementation guide.
Body Structure Qualifiers |
Additional body site qualifiers |
Codes which were needed, but not found in SNOMED or LOINC, will be submitted there |
Codes which were needed, but not found in SNOMED or LOINC, will be submitted there |
IOP Methods Code System |
IOP additional method types |
Visual field test parameter observations |
Visual field observation additional codes |
These are example instances that show what data produced and consumed by systems conforming with this implementation guide might look like.
These are resources that are used within this implementation guide that do not fit into one of the other categories.